Description : KF100 UV online environmental monitoring, industrial control, security monitoring

Stock : 1PC

MOQ : 1PC

Price : $10,000.00 - $20,000.00/sets

Model NO. : KF100

Sample Gas Input and Output Interface : ø 6 Tube Fittings

Size : 19''*3U*320mm

Resonse Time(T90) : Less Than 10s

Ambient temperature : 5℃-45℃

Power : 220VAC/50Hz 100W

Analog interface : 3-way 4-20mA switch input, 2-way 4-20mA output

Data interface : 4-way switch input, 8-way relay output

Communication Interface : 1-way RS-232, 1-way RS485(Supports Mod-bus protocol)

Protection Grade : IP42

Contact Now

KF100 Series Flue Gas Ultraviolet Analyzer for Industry SO2 NO NO2 O2 NH3 CL2 O3 H2S


The KF100 Flus Gas Ultraciolet Analyzer, based on UV absorption sepctroscopy technology and chemometric algorithms, can be used to measure the concentration of SO2, NOx, O2, NH3, CL2, O3, H2S and other gases. With high accuracy, high reliability, fast response, and wide applicability, it can be widely used in online environmental monitoring, industrial control, security monitoring and other occasions. The performance indicators of the KF100 series have reached or exceeded those of other domestic and foreign competing products.



>>>Technical Features

The analyzer gets the UV absorption spectrum from the following optical technology platform that consists of a light source, a gas chamber, fibre optics, a spectrometer(including a diaphragm, holographic gratings, and a linear array detector) and other optical components.

The UV-visible light emitted from the light source enters into the gas chamber through the optical windows, where it is absorbed by the sample gas flowing through the gas chamber. Then the light carrying the absorping information of the tested sample gas is converged by a lens and coupled inyp the optical fibre. After the light is transmitted into the spectrometer through the optical fibre for light splitting and sampling, the absorption spectrum of the gas can be obtained.

By using the DOAS technology to analyze the spectrum, the concentration of relevant contents in the gas can be analyzed.

>>>Technology Comparison

Item UV Hot-Wet Method NDIR
Spectral Range Complete and continuous absorption spectra obtained through holographic grating and diode array detection Non Dispersive, characteristic absorption spectra obtained through band-pass filter
Linear Response High wavelength resolution secures linear response band-pass filtration compromises linear response
SO2 Loss Hot-wet prohibits SO2 dissolution Condensation inevitably causes SO2 loss
Sampling System Heat tracing. Requests only dust filtration, simple and no corrosive Cold-dry. Requests dust filtration, condensation, water removal and corrosion proof
Zero Calibration Period Long (DOAS algorithm) Short
Anti-Interference The combination of complete & continuous absorption spectra, high wavelength resolution, DAOS algorithm erases interference from dust, moisture and background gases Vulnerable to moisture interference
Gas Cell Connected by optical fiber, easy to replace and low maintenance cost Complex to replace and maintenance
Maintenance
Reliability No moving parts Moving parts existed


>>>Technical Specifications

SO2, NOx Analyzer
Technical Principle UV-DOAS
Installation type Hot-wet Extractive
Measurement Range 0~200ppm, 0~1000ppm, 0~3000ppm
Zero Drift ≤ ±2%F.S.
Span Drift ≤ ±2%F.S.
Accuracy ≤ ±1%
Response Time(T90) ≤ 60s
Linearity ≤ ±1%F.S.
O2 Analyzer
Technical Principle Zirconia/Electrochemical
Measurement Range 0~25%
Response Time(T90) ≤ 60s
Linearity ≤ ±2%F.S.
CO, CO2 Analyzer
Technical Principle NDIR
Installation type Extractive
CO Measurement Range 0~1000 ppm
CO2 Measurement Range 0~20%
Zero Drift ≤ ±2%F.S.
Span Drift ≤ ±2%F.S.
Accuracy ≤ ±1%
Response Time(T90) ≤ 60s
Linearity ≤ ±2%F.S.


Technical Data for UV gas analyzer

Project Indicators
SO2 Detection range Min:0-50ppm,Max:0-100%,
NO Detection range Min:0-50ppm,Max:0-100%,
O2 Detection range 0-25%, Electrochemical or zirconia
Linearity error ≤±1%F.S.
Repeatability ≤1%
Zero drift ≤±1%F.S./ week
Span drift ≤±1%F.S./week
Ambient temperature 5ºC~45ºC
Response time(T90) <60s
Size 19" *3U*320mm
Analog interface 3-way 4-20mA output,2-way 4-20mA output
Data interface 4-way switch input; 8-way relay output
Communication Interface 1-way RS-232,1-way RS-485(Supports Mod-bus protocol)
Power 220VAC/50Hz 100W
Protection grade IP42
Sample gas input and output interface Ø6 Tube Fittings

>>>About Us

KF100 Series Flue Gas Ultraviolet Analyzer for Industry SO2 NO NO2 O2 NH3 CL2 O3 H2S



Product Tags:

Flue gas ultraviolet analyzer for SO2 NO NO2

      

Industrial UV gas analyzer for emissions

      

Ultra-low emissions monitoring system with warranty

      
China KF100 Series Flue Gas Ultraviolet Analyzer for Industry SO2 NO NO2 O2 NH3 CL2 O3 H2S wholesale